Home > Products > HC 6030 > Features Summary

Multifunctional Power Quality Meter HC 6030

Features
  • Metering of distribution feeders, transformers, generators, capacitor bands and motors
  • Medium and low voltage systems
  • Commercial, industrial, utility
  • Flexible control for demand load shedding, power factor, etc.
  • Power quality analysis.>
  • A / W / Var / VA demand
  • 8 digital inputs / pulse input totalizing
  • 3 controlled relay outputs
  • 3 analog process inputs
  • 4 isolated analog outputs to a transducer function
  • 2 pulse outputs based on KWH, KVarH, KVAH or AH
  • 8 channels for time of use to power energy
  • Load shedding
  • Power factor control
  • Event log
  • Minimum / maximum logger
  • Data trend logger
  • Waveform capture / harmonic analysis through 31rd
  • Triggered trace memory ( Fault recording )
  • Ports : RS232 front, RS485 rear
  • ModBus(R) RTU protocol Metering
Model & Ordering

        

 

Specification

        

  • All measured display scaled to primary readout
  • Stability : Temperature range (-10 to +50oC) , max. 100 ppm/oC
  • Display 5 digits to V / A / W / Var / VA / PF
  • Display 8 digits to WH / VarH
  • Note :
    • VP1 / VP2 / VP3 / VPE, phase to neutral voltage
    • VL1 / VL2 / VL3 / VLE, line to line voltage
    • A1 / A2 / A3 / AE/ A0, phase current
    • VPE / VLE / AE, 3 phase averaged
    • A0, neutral current
    • PF1 / PF2 / PF3, coincident to conversion element
    • WH / VarH accuracy vs limited input range
      • Voltage > 50V
      • Current > 10% of rating
      • PF > 0.5
      Main AC power input
  • Phase and wires
    • 3 phase 4 wires wye 3VTs
    • 3 phase 4 wires wye 2VTs
    • 3 phase 3 wires
    • Single phase 3 wires
    • Single phase 2 wires
  • Range
    • Voltage : 10~600V
    • Current : suitable for CT secondary rating (optional)
      • Maximum 7.5A for 5A rating
      • Maximum 1.2A for 1A rating
    • Power maximum 6500 ( W / Var / VA )
    • Frequency : 40 - 70Hz
  • Triggered trace memory / fault recording range
    • V < 600V
    • A < 8*rated
  • Burden
    • Voltage
      • < 0.2VA at 600V / phase
      • < 0.02VA at 120V / phase
    • Current < 0.1VA at 5A / phase
  • Overload capability
    • Current ( 5A )
      • 2 * rated continuous
      • 10 * rated 30 seconds
      • 25 * rated 2 seconds
      • 50 * rated 1 second
    • Voltage
      • 750V continuous
      • 1000V 10 seconds
      • 1200V 3 seconds
¡@


Hsiang Cheng Electric Corp. (C)(P)2007 | Ver. 3.2 | Legal Notice | Feedback | Sitemap | Contact