Home > Products > HC 6035 > Features Summary

Multifunctional Power Quality Meter HC 6035

Features
  • Over 20 power and energy parameters
  • Modbus(R) RTU / Modbus(R) TCP/IP
  • 3-AC current inputs, 5A or 1A (specified when ordering)
  • 3-AC voltage inputs, maximum 600V
  • True RMS conversion
  • Instant maximum and minimum logger
  • For factory and building automation
  • Measured parameters for V, A, W, Var, WH, VarH, PF, Frequency .....
  • Maximum demand control applicable
  • Build in RTC (real time clock)
  • Field programmable PT / CT ratio
  • Accuracy up to 0.25%
  • Low input burden 0.2VA (5A / 120V)
  • 3 communication Port RS-485 (rear), RS-232 (front), RJ-45 Ethernet
  • Open / short circuit protection for safety
  • Memory for all setup and energy data
  • Comprehensive self test diagnostic
  • "User Map" speed up communication (indirect accessing data)
  • Easy in field maintenance
Model & Ordering

        

 

Specification

        

  • Input
    • 3 - AC Currents ( Aa, Ab, Ac)
    • 3 - AC Voltage (Pa, Pb, Pc, Pn for 3-phase input)
    • Range
      • Voltage : 10 ~ 600 V
      • Current : Switch able for CT secondary rating, Maximum 6A for 5A rating, Maximum 1.2A for 1A rating
      • Frequency : 46 ~ 64 Hz
  • Burden
    • Voltage < 0.15VA at 300V (or > 1 M)
    • Current < 0.2VA of rating
    • Overload Withstand : 3 CT continuous, 25 CT 2 sec, 50 CT 1 sec; 2 PT continuous for voltage rating
  • Display
    • Standard : VFD / 3 rows of 8 alphanumeric
    • Option : LCD / 3 rows of 8 alphanumeric / Chinese sub-title
  • Programmability (comm. port and keyboard setting)
    • Communication Baud Rate / address : 1.2K / 2.4K / 4.8K / 9.6K / 19.2K / 38.4K bps, Address setting: 1 - 255
    • Measured Power System : 3P4W / 3P3W / 1P3W 50/60 Hz main frequency, PT ratio 1.0 ~ 5000.0, CT ratio 1.0 ~ 5000.0
  • Maximum / Minimum Logger
    • 20 parameters with time-stamped : VP1, VP2, VP3, VPE, VPS, VL1, VL2, VL3, VLE, VLS, A1, A2, A3, A0, AE, W, Var, VA, PF, F
  • Communication Port
    • RS232 (front panel) : Maintenance only
    • RS485 (rear panel) : Modbus(R) RTU
  • Ethernet Port
    • One 10/100 base-T Ethernet interface (RJ-45)
    • Modbus(R) TCP/IP
  • Digital input (DI) .... option
    • 8 status input with one common point
  • Digital onput (DO) .... option
    • 6 select relay ("a" contact)
    • Contact rating 3A (250Vac / 30Vdc)
  • Real Time Clock (RTC)
    • Maximum deviation 2 sec in 24 hours
    • Time for Year / Month / Day / Hour / Minute / Second
  • Dielectric Strength
    • IEC 255-5
    • 2KV AC rms 1 minute between input / power / case, 1.6KV AC rms 1 minute between input / output ; output / power
  • Impulse and Surge
    • ANSI / IEEE C37.90.1-1989 (3KV) SWC
    • IEC 61000-4-12 CLASS III SWC
    • IEC 61000-4-4 CLASS IV SWC
    • IEC 61000-4-5 CLASS IV Impulse
  • CE Statement of conformity
    • RFI Emission : EN 61326 : 1997+A1 : 1998+A2 : 2001+A3 : 2003, EN 61000-3-2:2000+A2:2005, EN 61000-3-3:1995+A1:2001
  • Stability
    • Temperature range (-10 to +60oC), maximum 100 ppm/oC
  • Operating Condition
    • Temperature range -25 to 60oC, RH 10 to 95% non-condensing
  • Storage Condition
    • Temperature range -40 to 80oC, RH 10 to 95% non-condensing
  • Power Supply
    • LO : DC 20 ~ 60V
    • HI : AC 80 ~ 260V @ 40 ~ 70 Hz, DC 90 ~ 330 V
    • Dissipation maximum 12 VA for AC and 8W for DC
  • Dimension
    • 144 * 144 * 100 mm , panel mount, terminal connection type
  • Case
    • Polyester ABS : UL94 Class V-0
  • CUT OUT
    • 138+1 * 138+1 mm
¡@


Hsiang Cheng Electric Corp. (C)(P)2007 | Ver. 3.2 | Legal Notice | Feedback | Sitemap | Contact