  • Over 90 power and energy parameters
  • Modbus RTU protocol
  • 3-AC voltage inputs, maximum 300V; 3-AC current inputs, 5A or 1A (specified when ordering)
  • 4-AC voltage inputs include separate 1-phase input, maximum 300V; 4-AC current inputs include neutral current, 5A or 1A (specified when ordering)
  • True RMS conversion
  • 32 sample points per cycle
  • Instant maximum and minimum logger
  • Data logger
  • Trend logger (option)
  • Waveform capture
  • Harmonic analysis for power quality analysis (up to 15th harmonic)
  • 200 event logs for all measured quantities
  • Build in RTC (real time clock)
  • Field programmable PT / CT ratio
  • Accuracy up to 0.2%
  • Low input burden 0.15VA (5A / 120V)
  • 2 communication Port, RS-485 + RS-232
  • Wide power supply range 80~260V AC / DC
  • Memory for all setup and energy data
  • Comprehensive self test diagnostic
  • "User Map" speed up communication (indirect accessing data)
  • Alarm setting (under / over) for voltage and current
  • Synchrocheck (4-AC voltage inputs only)
  • One binary output for overcurrent (DO)
  • Fault current detection (option)
  • 2KV RMS input / output / power isolation
Model & Ordering

        

 

Specification
        

  • Input
    • 4 - AC Currents (Aa, Ab, Ac, A0) , if 3 - AC current input then A0 for calculated
    • 4 - AC Voltage (Pa, Pb, Pc, Pn for 3 phase input & P1, P2 for separate 1 phase input) , if 3 - AC voltage inputs then none P1, P2
    • Range
      • Voltage : 10~300 V
      • Current : Switchable for CT secondary rating, Maximum 6A for 5A rating, Maximum 1.2A for 1A rating, AFx : 20 x CT (fault current)
      • Frequency : 40 ~ 70 Hz
  • Burden
    • Voltage < 0.15VA at 300V (or > 1M )
    • Current < 0.2VA of rating
    • Overload withstand : 2 CT continuous, 25 CT 2 sec, 50 CT 1 sec
  • Programmability
    • Communication Baud Rate
      • 1.2k / 2.4k / 4.8k / 9.6k / 19.2k bps
      • Device address 1-254
    • Measured Power System
      • 3P4W / 3P3W / 1P3W / 1P2W
      • 50 / 60 Hz main frequency
        • PT ratio 1.0 ~ 5000.0
        • CT ratio 1.0 ~ 5000.0
      • Max demand 1 ~ 60 minute (A, KW, KVAR, KVA)
  • Fault Current Detection (Mode 0)
    • One Fault-Based-Curve
    • 16 set-point groups (Ip-pu, Mp, Ig-pu, Mg)
  • Fault Current Detection (Mode 1)
    • User definable
    • 4-point phase time over-current curve
    • 4-point ground time over-current curve
  • Communication Port
    • 2 communication port maximum
    • Modbus RTU protocol
  • Real Time Clock (RTC)
    • Maximum deviation 2 sec in 24 hours
    • Time for Year / Month / Day / Hour / Minute / Second
  • Dielectric Strength
    • IEC 255-5
    • 2KV AC rms 1 minute between input / output / power
  • Impulse and Surge
    • ANSI / IEEE C37.90.1-1989 (3KV) SWC
    • IEC 61000-4-12 CLASS III SWC
    • IEC 61000-4-4 CLASS IV SWC
    • IEC 61000-4-5 CLASS IV Impulse
  • Stability
    • Temperature range (-10 to +50oC)
    • Maximum 100 ppm /oC
  • Operating Condition
    • Temperature range -25 to 60oC
    • RH 10 to 95% non-condensing
  • Storage Condition
    • Temperature range -40 to 80oC
    • RH 10 to 95% non-condensing
  • Power Supply
    • LO : DC 20 ~ 60V
    • HI : AC 80 ~ 260V @ 40 ~ 70 Hz, DC 80 ~ 330 V
    • Dissipation maximum 12 VA for AC and 5W for DC
  • Dimension
    • 134.8 * 70.3 * 149.5 mm, DIN Rail-Mounting
  • Digital output (DO)
    • High voltage, solid state relay - MOSFET output
    • control 200V AC or DC voltage, switch 50mA load
    • Isolation 3750V AC rms
  • Waveform Capture
    • Data Channel : 4 currents, 4 voltages
    • Sample Rate : 32 points per cycle, length 2 cycle
  • Event logger
    • 200 events with time-stamped
    • Failure in self-test
    • Programming access
    • Fault current recorder
    • Power ON / OFF
  • Trend logger
    • 20 parameters with time-stamped : VP1, VP2, VP3, VPE, VPS, VL1, VL2, VL3, VLE, VLS, A1, A2, A3, A0, AE, W, Var, VA, PF, FQ, Vubl, Aubl
    • Sample rate 15 / 30 / 60 minute per sample
    • Length 960 datas / parameter
    • Length 10 days / 15 minutes, 40 days / 60 minutes
  • Maximum / Minimum Logger
    • 20 parameters with time-stamped : VP1, VP2, VP3, VPE, VPS, VL1, VL2, VL3, VLE, VLS, A1, A2, A3, A0, AE, W, Var, VA, PF, F
¡@