Features
- True process dc rate
- Input of pressure sensor output
- Rangeable of display scale for engineering unit
- High accuracy of 0.1%
- Option of dc linearty output or 24Vdc power output
- 3-3/4 digits of maximum 3999 counts
- Dispaly with super rate LED
Model & Ordering

Specification
- Accuracy (23 + 3oC) : 0.1% fs + 1 count
- Stability : Temp. coeficient < 60 ppm per degree C, long term draft < 0.1% per year
- Digits & Display : 3-3/4 digits of maximum 3999 counts, 0.56+-super rate LED
- Input range : Span minimum 0-2.5mV to maximum 0-110mV
- Configuration :
- Switchable span gain & offset adjustment for 0 to +-4000 display counts.
- Selectable of decimal point
- Exciting voltage : Selectable 5 or 10 DC voltages with load capability, 45 mA maximum
- Response time : Sample rate 1 of per sec typically
- Input resistance > 10 Megohms maximum
- Noise rejection Cmrr > 120db, Nrmm > 100 db
- Common made voltage : 2KVrms / 1 minute, 50 / 60 Hz
- Operating condition : -10 to 55oC, 0-99% RH non-condensed
- Storage condition : -25 to 70oC, 20-99% RH non-condensed
- Auxiliary power : AC + 15% < 3.5 VA, DC + 20% < 5 watts
¡@ |