Features
- Programmable for PT & CT ratio
- True power system design compliants: ANSI-IEEE, IEC & VED standards
- High over capability
- 7 digits counter
- High accuracy of 0.2%
- Distorted waveform signal measurement
- Display with super rate LED
Applied rules & standards
- Measuring and conversion : IEC 60687
- Dielectric strength : IEC 60255-5
- Impulse / surge test :
- ANSI / IEEE
- C37.90.1-1989 (3KV) SWC
- IEC 61000-4-12 class III SWC
- IEC 61000-4-4 class IV SWC
- IEC 61000-4-5 class IV Impulse
- Adaptability power system : IEC 0110
- Measuring reliability VDE : 3540
Model & Ordering

Specification
- Accuracy (23 + 3oC) :
- 00.2% rd / PF (PF = cosØ for WH version¡FPF = sinØ for VarH version)
- Output pulse :
- Photo couple isolator, open colector 30V, 50mA maximum
- 150mA maximum for 1/10/100 pulse / unit
- Ratio setting :
- PT ratio, range 1.0 ~ 5000.0
- CT ratio, range 1.0 ~ 5000.0
- Stability :
- Temperature range -10 ~ +50oC, maximum 70ppm/oC
- Digits & counts :
- Seven (7) digits 9999999 counts maximum
- Response time :
- Conversional rate less 1 sec typically
- Input burden :
- 0.2VA maximum per input element
- Input over :
- Current input :
- 2 * rating continuous
- 25 * rating - 2 sec
- 50 * rating - 1 sec
- Voltage input : 1.5 * rating continuous
- Dielectric strength :
- 2.5KVrms / 1 minute, all terminals to FG
- 2KVrms / 1 minute, between input / output / power
- Impulse and surge :
- ANSI/IEEE C37.90.1-1989 (3KV) SWC
- IEC 61000-4-12 class III SWC
- IEC 61000-4-4 class IV SWC
- IEC 61000-4-5 class IV Impulse
- Operating condition :
- Operating temperature range -25 ~ 60oC, RH 0 to 95% non-condensing
- Storage temperature range -40 ~ 80oC, RH 0 to 95% non-condensing
- Power supply :
- Lo : DC 20 ~ 60V
- Hi : AC 80 ~ 260V @40-70Hz, DC 80 ~ 330V
- Dissipation maximum : 10 VA for AC and 5 Watt for DC
¡@ |