Model & Ordering
MODEL : PTC 8300D
Specification
- Accuracy : Output voltage, current, and power : 0.1%
- Output voltage and current distortion < 0.5% (if it is a linear load)
- Output power stability The variation of pre-set output power within 180S will < 0.02% compared with the measurement range
- Electric quantity symmetry among the three phases The difference between any line voltage or phase voltage is < 0.2%; the difference between any phase current, the value is not < 0.2%; the difference between any phase current, the corresponding phase is < 0.2o
- Harmonic wave setting :
- Number of harmonic wave : 2 - 21
- Content of harmonic wave < 40% (compared with base wave)
- Phase of harmonic wave : 0o - 359.9o
- HC 3100B standard reference meter
- Able to test V, A, W, Var, VA, Watthour, Varhour, F, PF, Ø (including sine wave, 90o, 60o reactive power)
- Accuracy : 0.1 / 0.05%
- Input voltage : 3 * 440 / 600 VY / ŁG
- Input current : 3 * 100A
- Input frequency : 40 - 70Hz
- Communication part : RS-232
- Display digit : 6 bit
- Temperature influence : max 10PPM / oC
- Power supply AC single-phase 220V / 240V, (100V / 110V also available), 50 / 60Hz, maximum input power consumption : 500W
- Outer dimensions : 480 * 550 * 178 mm
ˇ@ |