Home > Products > PTC 8320E > Features Summary

Energy Meter Test Bench PTC 8320E

Features
  • Close-link and ordinary calibration both can be used, ordinary calibration can be used to test single / three phase active and reactive energy meter (up to 0.5 class), close-link calibration can be used to test single / three phase active and reactive energy meter (up to 1 class).
  • The bench can test the converted quantity which is caused by negative phase, voltage unbalance, harmonic wave and so on.
  • The bench can auto-calibrate starting, no load, basic error and calibration tolerance and 24 deflection.
  • Close-link calibration is using insulate current transformer and suitable for close-link energy meter.

 

Specification
  • Accuracy of test bench :
    • 0.2% (close - link calibration, current : 0.25A - 120A)
    • 0.05 / 0.1% (ordinary calibration)
  • Reference standard meter HC 3100 three phase multi-functions precision power testing instrument Accuracy : 0.05%
  • Isolated current transformer equipment PTC-9503B insulate current inductance
    • Accuracy : 0.1% (cosØ = 0.5C - 1 - 0.5L, 0.25 - 120A)
    • Primary current : 3 * 0.25 - 120A
    • Secondary current : 3 * 0.25 - 120A
    • Output power : 30VA (max. 100A)
  • Voltage amplifier:
    • Output voltage : 30 - 400V (phase - neutral); 50 - 600V (phase - phase)
    • Output maximum power : 800VA
                  
  • Current amplifier :
    • Output current : 1mA - 120A
    • Output maximum power : 1500VA
  • For voltage / current amplifier
    • Resolution : 0.01%
    • Stability < 0.05% / 3 min (time base 5S)
    • Distortion factor < 0.5% at linear load
    • Frequency : 45 - 65 Hz
    • Power efficiency > 85%
    • Electronic overload protection and security for open current circuit.
  • Phase Angle : 0o - 360o, Resolution of phase angle setting : 0.1o
  • Output frequency : 45 - 65 Hz; resolution : 0.01 Hz
  • Harmonic wave output :
    • 2 - 21 sub - harmonic wave, contents < 40%
    • 3, 5, 7 sub - harmonic wave coupling, total content < 40%
    • Phase angle control (odd sub - harmonic wave)
    • Wave group control (sub - harmonic wave)
  • Output stability of power < 0.05% (180S)
  • Input power : 3 * 220V / 380V(Y) +15%, 50 / 60 Hz; Power consumption : max. 6000VA
  • Dimension :
              
¡@


Hsiang Cheng Electric Corp. (C)(P)2007 | Ver. 3.2 | Legal Notice | Feedback | Sitemap | Contact