Features
- True Process DC rate monitor
- Wide standard DC voltage & current input
- Rangeable of display scale for engineering unit
- High accuracy of 0.2%
- Two wire application
- 4-1/2 digits of maximum +19999 counts
- Display with supper rate LED
Model & Ordering

Specification
- Accruacy (23 + 3oC) : 0.2% fs
- Stability : Temperature coefficient < 50 ppm per degree C. Long term draft < 0.1% per year
- Display & resolution : 0.56" super rate LED, 4-1/2 digits of maximum +19999 counts
- Response time : Sample rate 1 sec typically
- Input resistance > 1M
for voltage input, < 20 for current input
- Input over : Maximum 1 ampere for current input, maximum 250V for voltage input
- Noise rejection : CMRR > 120dB, NMRR > 100dB
- Common mode : voltage 2KV rms / 1 minute
- Operating condition :
- Temperature range -10 to 55oC, 0 to 99% RH non-condensed
- Storage -25 to 70oC, 20-99% RH non-condensed
- Auxiliary power : AC / DC version < 3.5VA, DC option version +20% < 5 watts
¡@ |