Features
- Current input terminal with automatic shorting mechanism
- Over 90 power and energy parameters
- Modbus(R) RTU / DNP3.0 protocol
- 4-AC current inputs, 5A or 1A (specified when ordering)
- 4-AC voltage inputs, maximum 300V
- True RMS conversion
- 32 sample points per cycle
- Instant maximum and minimum logger
- Waveform capture
- Error message display
- 200 event logs for all measured quantities
- Build in RTC (real time clock)
- Field programmable PT / CT ratio
- Accuracy up to 0.15%
- Low input burden 0.5VA (5A / 120V)
- 2 communication Port, RS-485 + RS-232
- Wide power supply range 80~260V AC / DC
- Memory for all setup and energy data
- Comprehensive self test diagnostic
- "User Map" speed up communication (indirect accessing data)
- Synchrocheck
- Fault current detection .....option
- 2KV RMS input / output / power isolation
- Alphanumeric LED display clear and long-life
- Fully modularized & plug-in type
- Easy in field maintenance
Model & Ordering

Specification

Input
- 4 - AC Currents ( Aa, Ab, Ac, A0)
- 4 - AC Voltage (Pa, Pb, Pc, Pn for 3-phase input & P1, P2 for separate 1-phase input)
- Range :
- Voltage : 10~300V
- Current : Switch able for CT secondary rating
- Maximum 6A for 5A rating
- Maximum 1.2A for 1A rating
- AFx=20CT (Fault current) .....option
- Frequency 40-70Hz
Burden
- Voltage < 0.15VA at 300V (or > 1 M
)
- Current < 0.2VA of rating * Overload Withstand: 2 CT continuous, 25 CT 2 sec, 50 CT 1 sec
Display
- LED / 0.2" / green color, 1 rows of 8 characters
Programmability
- Communication Baud Rate
- 1.2K / 2.4K / 4.8K / 9.6K / 19.2K bps, Device address 1 ~ 254
- Measured Power System
- 3P4W / 3P3W / 1P3W / 1P2W, 50 / 60 Hz main frequency
- PT ratio 1.0~5000.0
- CT ratio 1.0~5000.0
- Maximum demand 1-60 minute (A,KW,KVAR,KVA)
Fault Current Detection (Mode 0) ..... option
- One Fault-Based-Curve
- 16 set-point groups (Ip-pu, Mp, Ig-pu, Mg)
Fault Current Detection (Mode 1) ..... option
- User definable
- 4-point Phase time over-current curve
- 4-point Ground time over-current curve
Waveform Capture
- Data Channel : 4 currents, 4 voltages
- Sample Rate : 32 points per cycle, length 2 cycle
Maximum / Minimum Logger
- 20 parameters with time-stamped : VP1, VP2, VP3, VPE, VPS, VL1, VL2, VL3, VLE, VLS, A1, A2, A3, A0, AE, W, Var, VA, PF, F
Communication Port
- RS232 (front panel) : Modbus RTU protocol only
- RS485 (rear panel) : Modbus RTU or DNP3.0 protocol
Real Time Clock (RTC)
- Maximum deviation 2 sec in 24 hours
- Time for Year / Month / Day / Hour / Minute / Second
Dielectric Strength
- IEC 255-5
- 2KV AC rms 1 minute between input / output / power
- 2.5KV AC rms 1 minute between case / input
- 2KV AC rms 1 minute between case / power
Impulse and Surge
- ANSI / IEEE C37.90.1-1989 (3KV) SWC
- IEC 61000-4-12 CLASS III SWC
- IEC 61000-4-4 CLASS IV SWC
- IEC 61000-4-5 CLASS IV Impulse
Stability
- Temperature range (-10 to +50oC), maximum 100 ppm/oC
Operating Condition
- Temperature range -25 to 60oC, RH 10 to 95% non-condensing
Storage Condition
- Temperature range -40 to 80oC, RH 10 to 95% non-condensing
Event logger
- 200 events with time-stamped
- status change of switch input
- Failure in self-test
- Programming access
- Fault current recorder .....option
- Power ON / OFF
Power Supply
- LO : DC 20~60V
- HI : AC 80~260V @ 40~70 Hz, DC 80~330 V
- Dissipation maximum 12 VA for AC and 5W for DC
Dimension
- 208 * 72.6 * 144.6 mm (L * W * H)
¡@ |