Products

Post it to Twitter Post it to Facebook

HC 6035 

Model: HC 6035
Name: Multifunctional Power Quality Meter
Description:

  • Over 20 power and energy parameters
  • Modbus(R) RTU / Modbus(R) TCP/IP
  • 3-AC current inputs, 5A or 1A (specified upon ordering)
  • 3-AC voltage inputs, maximum 600V
  • True RMS conversion


Overview
The HC 6035 Power Meter is microprocessor-based instrument intended for power and energy measurement.
The HC 6035 is an Intelligent Electronic Device (IED) and stores these measured values and setting parameters in internal registers for communication. With the features, high accuracy, fully modularized design, and compact size,
HC 6035 is very suitable for Electric Utility Substation Automation application.
This product is solely made and manufactured by the Taiwan Hsiang Cheng Electric Corp.
Hsiang Cheng Electric Corp. reserves the right to all research and development designs for this model.

Features
•Over 20 power and energy parameters available
•Modbus(R) RTU / Modbus(R) TCP/IP
•3-AC current inputs, 5A or 1A (specified upon ordering)
•3-AC voltage inputs, maximum 600V
•True RMS conversion
•Instant maximum and minimum logger
•For factory and building automation
•Measured parameters for V, A, W, Var, WH, VarH, PF, Frequency .....
•Maximum demand control applicable
•Build in RTC (real time clock)
•Field programmable PT / CT ratio
•Accuracy up to 0.25%
•Low input burden 0.2VA (5A / 120V)
•3 communication Port RS-485 (rear), RS-232 (front), RJ-45 Ethernet
•Open / short circuit protection for safety
•Memory for all setup and energy data
•Comprehensive self test diagnostic
•"User Map" speed up communication (indirect accessing data)
•Easy in field maintenance

Model & Ordering
 
Specifications
Programmable measurements / Accuracy / Display readouts
         

  • Input

            o3 - AC Currents ( Aa, Ab, Ac)
            o3 - AC Voltage (Pa, Pb, Pc, Pn for 3-phase input)
            oRange
              ♦Voltage : 10 ~ 600 V
              ♦Current : Switch able for CT secondary rating,
                                 Maximum 6A for 5A rating,
                                 Maximum 1.2A for 1A rating
              ♦Frequency : 46 ~ 64 Hz

  • Burden

             oVoltage < 0.15VA at 300V (or > 1 M )
             oCurrent < 0.2VA of rating
             oOverload Withstand : 3 CT continuous,
                                                      25 CT 2 sec, 50 CT 1 sec;
                                                      2 PT continuous for voltage rating

  • Display

              oStandard : VFD / 3 rows of 8 alphanumeric positions
              oOptional : LCD / 3 rows of 8 alphanumeric positions / Chinese sub-titles available

  • Programmability (comm. port and keyboard setting)

             oCommunication Baud Rate / address :
                1.2K / 2.4K / 4.8K / 9.6K / 19.2K / 38.4K bps,
                Address setting: 1 - 255
             oMeasured Power System : 3P4W / 3P3W / 1P3W 50/60 Hz main frequency,
                PT ratio 1.0 ~ 5000.0, CT ratio 1.0 ~ 5000.0

  • Maximum / Minimum Logger

             o20 parameters with time-stamp:
                     VP1, VP2, VP3, VPE, VPS, VL1, VL2, VL3, VLE,
                     VLS, A1, A2, A3, A0, AE, W, Var, VA, PF, F

  • Communication Port

             oRS232 (front panel): Maintenance only
             oRS485 (rear panel): Modbus(R) RTU

  • Ethernet Port

             oOne 10/100 base-T Ethernet interface (RJ-45)
             oModbus(R) TCP/IP

  • Digital input (DI) .... optional

              o8 status input with one common point

  • Digital onput (DO) .... optional

             o6 select relay ("a" contact)
             oContact rating 3A (250Vac / 30Vdc)

  • Real Time Clock (RTC)

            oMaximum deviation 2 sec in 24 hours
            oTime for Year / Month / Day / Hour / Minute / Second

  • Dielectric Strength

            oIEC 255-5
            o2KV AC rms 1 minute between input / power / case,
            1.6KV AC rms 1 minute between input / output; output / power

  • Impule and Surge

            oANSI / IEEE C37.90.1-1989 (3KV) SWC
            oIEC 61000-4-12 CLASS III SWC
            oIEC 61000-4-4 CLASS IV SWC
            oIEC 61000-4-5 CLASS IV Impulse

  • CE Statement of conformity

            oRFI Emission :
              EN 61326: 1997+A1: 1998+A2: 2001+A3: 2003,
              EN 61000-3-2:2000+A2:2005,
              EN 61000-3-3:1995+A1:2001

  • Stability

            oTemperature range (-10 to +60oC), maximum 100 ppm/oC

  • Operating Condition

            oTemperature range -25 to 60oC, RH 10 to 95% non-condensing

  • Storage Condition

           oTemperature range -40 to 80oC, RH 10 to 95% non-condensing

  • Power Supply

           oLO : DC 20 ~ 60V
           oHI : AC 80 ~ 260V @ 40 ~ 70 Hz, DC 90 ~ 330 V
           oDissiption maximum 12 VA for AC and 8W for DC

  • Dimensions

           o144 * 144 * 100 mm,
              panel mount, terminal connection type

  • Case

          oPolyester ABS : UL94 Class V-0

  • CUT OUT

          o138+1 * 138+1 mm