Power Transducer

UPPD-1

HC PP/UPP series transmitters are a family of plugging unit type, set in a standard DIN 19" rack mounting or in an independent unit-enclosure which according to user application. Each plugging unit is designed & divided into two parts : input terminal module & converting module.

UPPD-1 is the plug-in type DC Isolating transducer with one output.
Measuring and conversion of IEC 688 . The adaptability for power system of VDE 0110, and Measuring reliability of VDE 3540. 


*The PP series is a traditional analog product, and the UPP series is a new digital product. PP series products are partly replaced by UPP series, the input and output terminals and functions are the same, and can be directly replaced.
 
 
  • Field – range ability : wide switchable input ranges, 10mV~200V / 200uA~50mA
  • Wide switchable output ranges, over 20 standard process signals
  • Accuracy 0.2%
  • High dielectric strength 4KV AC rms input / output / power / case
  • Available standard or custom calibration
 
  • Accuracy (23±5°C) : 0.2% RO
  • Linearity & repeatability : 0.1% typical
  • Temperature stability : Less 0.008% ro per degree C
  • Configuration :
    • Field range ability
    • Switchable input, span of DCV 10mV to 200V, DCmA of 0.2 to 50mA
    • Switchable output over 20 standard signals
  • Input resistance - OHM :
    • Voltage mode
      • > 10MΩ of 2V & lower ranges
      • > 500KΩ of higher 2V ranges
    • 200Ω of all current input ranges
  • Maximum input over :
    • Maximum 300V rms continuous of > 2V ranges
    • Maximum 150V rms continuous of 2V & lower ranges
    • Maximum 150mA continuous for all current input
  • Power effect : Less than 0.003% per volt change
  • Response time & ripple : Less 400ms typically, ripple less 0.1% ro
  • Common mode rejection > 120db, DC to 60Hz
  • Dielectric strength : 4KV AC between input / output / power / case
  • Impulse & surge test : IEEE 587 / 1983 or IEC 255-4
  • Output drive capability : Maximum 10mA for voltage mode, maximum 10V for current mode
  • Storage condition : Temperature range -25 to +70°C, RH 20 to 95% non condensed
  • Operating condition : Temperature range -20 to +65°C, RH 20 to 95% non condensed
  • Power supply :
    • LO : DC 24 - 60V ± 20%
    • HI : AC 80 - 260V @40 - 70Hz / DC 80 - 330V
    • Dissipation Max. 12VA for AC / 10W for DC
  • Dimension : W*H*D : 12T (60.6mm) * 3U (128.5mm) * 238mm