Power Transducer

FPD-Metal Case

HC FP series transducer are a family of metal case transducer for Measuring and conversion of IEC 688 / 1992 - 04, set in a Wall Mount.
FPD is the one unit DC voltage/current transducer with one output.
  • Accuracy ( 23 ± 3 °C ) : 0.25% of effecive range
  • Linearty & repeatability : 0.05% typical
  • Dielectric strength : 
    • 1500Vac ... power / input & output terminals
    • 1800Vac ... input / output / case
  • Maximum output load :
    • DC current mode : maximum 10V drop
    • DC voltage mode : maximum 10mA drive
  • Maximum input over:
    • ≦ 300Vrms continuous ... > 2V ranges
    • ≦ 150Vrms continuous ... ≦ 2V ranges
    • ≦ 150mA continuous for current input
  • Input resistance-ohm : 
    • ≧ 100M ... ≦ 2V ranges, ≧ 500K ... >2V ranges
    • ≦ 20 ... for all current input range
  • Power effect : < 0.003% for per volt change
  • Response time & ripple : 250 ms typically, ripple < 0.1% rms ro
  • Common mode rejection : 120dB, DC to 60Hz
  • Temperatured stability : ≦ 0.007% ro per degree C
  • Storage condition : Temperature range -10 to 70°C, RH 20 to 95% non condensed
  • Operating condition : Temperature range -5 to 55°C, RH 20 to 95% non condensed
  • Power supply : 
    • ±10% of rated, less 3.5 VA for AC input
    • ±10% of rated, less 3.5 Watt for DC input
  • Construction : Socket plug-in type with barrier terminals

Certifications

  • CE
TOP