電力轉換器

SPW301-Metal Case

HC SP系列設計使用堅固的鋼製外殼,具有良好的抗電磁干擾能力及較高的電氣過載能力。是具有穩定可靠的量測單元,適用於現場操作及實驗室。

SPW-WATT利用乘法器進行電壓及電流的轉換進而計算出瓦特數值,設計為精準量測單。

SPW301適用於3相4線三元件系統
 
  •  0 to 1 mAdc 標準輸出
  • 精確為0.25% 讀值 + 0.02% 範圍值
  • 具有抗高磁場干擾能力
  • 符合IEEE SWC 測試標準
  • Accuracy : 0.25% RD + 0.02%RO / 23 ± 3 oC
  • Input ( each element ) :
  • Range : Effective voltage 85-150V; current 0-6A
  • Over capability :
  • Voltage 200V continuous 250V ... 10sec / hour; 500V ... 2sec / hour
  • Current 15A continuous 50A ... 10sec / hour; 250A...1sec / hour; 400A ... 0.5sec / hour
  • Burden : Voltage < 0.1VA at 120V input; current < 0.2VA at 5A input
  • Frequency : Watt 57-63Hz; Var 60Hz only
  • Protection : Full protection for SURGE, EMI & RFI
  • Output ( isolated with input ) :
  • Range :
  • DC 0 to ± 1mA
  • DC 0 to ± 1mA calibration vs 0 to ± 500W / ± 500Var ...1ø2W / 1element
  • 0 to ± 1000W / ± 1000Var...3ø3W / 2elements
  • 0 to ±1 500W / ± 1500Var...3ø4W / 3elements
  • Output load : Maximum 10Kohm for 0 to +1 mA output
  • Output impedance > 30 Mega ohm
  • Response time < 400 ms from 0 to 99% RO at operating
  • Ripple < 0.5% P-P RO
  • Long term stability < 0.1% RO per year ( typically )
  • Temperature stability < 0.01% per degree C, from 0 to 55oC
  • Adjustment : Span +5% / 10%; zero +2.5% / 5% on request
  • Protection : No damage ... open or short; full protection for SURGE, EMI, & RFI
  • Magnetic effect < 0.04% at center 400 A-T / M
  • Power Supply : AC 115 + 20%, 50-70Hz, < 3VA
  • Operation Condition :
  • Temperature Environment: -5 ~ 60 oC
  • Humidity : 20~99% RH non condensed
  • Elevation : Under 3000 meters
  • Magnetic Field : 500 A-T / M
  • Waveform :
  • Watt - Fundamental with 20% 3rd harmonics
  • Var - Sinusoidal
  • Power Factor : Any
  • Dielectric strength : 4KV AC rms 1 minute between input / output / power / case;
  • fulfills IEC688 standards
  • Impulse Test : ANSI C37.90 / 1989, IEEE 587 / 1983, IEC255-3, 6KV (1.2 * 50 us), 3KA (8 * 20 us) ..... current only
  • Surge Test (ring wave) : IEEE 587 / 1983 (3KV - 0.5 us / 100 KHz), IEC255-3 (2.5KV - 0.25ms / 1MHz)